Sign In | Join Free | My burrillandco.com
Home > CT PT Test Equipment >

CT PT 220KV Portable Test Equipment With PC Communication Interface

    Buy cheap CT PT 220KV Portable Test Equipment With PC Communication Interface from wholesalers
     
    Buy cheap CT PT 220KV Portable Test Equipment With PC Communication Interface from wholesalers
    • Buy cheap CT PT 220KV Portable Test Equipment With PC Communication Interface from wholesalers

    CT PT 220KV Portable Test Equipment With PC Communication Interface

    Ask Lasest Price
    Brand Name : HNMC
    Model Number : HES-30
    Price : Negotiable
    Supply Ability : 5 sets per month
    Delivery Time : 30-45 days
    • Product Details
    • Company Profile

    CT PT 220KV Portable Test Equipment With PC Communication Interface


    CT PT TEST Equipment System HES-30


    Configuration

    Standard CT, ±0.01S%
    Standard PT (6kV-38.5kV), ±0.05%
    Standard PT (110/√3kV, 220/√3kV), ±0.05%
    CT Burden (5A, 1A), ±3%
    PT Burden (100V, 100/√3V, 100/3V), ±3%
    PT Burden (110V, 110/√3V, 110/3V), ±3%
    Transformer Tester (Calibrator), ±2%
    Current generator
    Voltage Generator
    Resonant high voltage source
    Induction voltage divider
    Secondary Test Cables
    PC Test Software
    CT PT Test Control Bench

    Technical Parameter


    HES-30 CT/PT Test Control Bench


    Input Voltage:AC 220V±10%, 50Hz, Single-Phase
    Input Current:AC 0-120A
    Rated Capacity:30kVA
    Output Voltage:AC 0-250V
    Output Current:AC 0-120A
    Output Voltage Adjustment:Provided the Coarse adjustment & Fine adjustment
    Protection function:Provided over current & overvoltage protection
    Output conversion functions:Connect to Current source / Voltage source conversion functions
    The Bench Structure:Horizontal structure
    Power Indicator:LED, Output current, Output voltage
    Color of the Bench7035 Gray

    HES-1Bx Transformer Tester

    Measure item:Ratio errors & Phase errors of the CT and PT
    Rated current:5A, 1A
    Rated voltage:100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V
    Multiplier:1/√3, 1/3, 1, 1.5, 2
    Accuracy class:±2%
    Operation range:(1%-120%).In, (20%-120%).Un
    Frequency:50Hz or 60Hz
    Ratio error range:±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%).
    Minimum resolution:0.0001%.
    Phase error range:0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900')
    Minimum resolution: 0.01'
    Impedance range:0.001Ω~ 19.99Ω.
    Minimum resolution: 0.001Ω.
    Admittance range:0.001 ms ~ 19.99 ms.
    Minimum resolution:0.001 ms.
    Alarm Function:Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.

    Input Load:

    - On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0

    - On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0

    - On Standard PT secondary side: ≈0.05VA (100V)

    Communication Interface:Provided the RS232 serial PC communication interface
    Display model:LCD
    Power supply:AC 220V±10%, 60Hz
    Power consumption:< 20VA
    Product Type:Portable type.

    CT Burden FY47-49

    Rated Current:5A, 1A

    Power Factor

    and Rated Burden:

    In=5A:

    COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

    COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

    (more option available)

    In=1A:

    COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

    COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

    (more option available)

    Accuracy Class:±3%
    Operation Range:(1%-120%). In
    Frequency:50Hz or 60Hz
    Withstand Voltage:2kV/1min
    Insulation:Air
    Operating Model:Short-time (Used in CT Accuracy Testing System)
    Product Type:Portable type.

    High-current Test Cables of the CT

    Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc

    500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs


    HLB-50G1 Standard CT



    Rated Primary Current(A):

    5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A

    (more option available)

    Rated Secondary Current:5A, 1A
    Rated Current Ratio:5A~5000A/5A, 5A~5000A/1A (more option available)
    Accuracy Class:0.01S% (0.05%, 0.02%, 0.01% or better are available)
    Rated Secondary Burden:0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A)
    Power Factor:COSΦ=1.0
    Operating Range:(1%-120%). In

    Connection Mode:

    Fixed connection terminals at Pri.current range is 5A-450A

    Pass-through connection with 2 turns at Pri.current range is 500A-900A

    Pass-through connection with 1 turn at Pri.current range is 1000A-5000A

    Frequency:50Hz or 60Hz
    Voltage Level:AC 600V
    Withstand Voltage:2000V 1min
    Insulating Medium:Air

    SLQ-30KVA Current Generator


    Input Voltage:AC 0-250V
    Output Current:AC 0-5000A
    Rated Capacity:30kVA
    Rated Input Current:AC 120A
    Frequency:50Hz or 60Hz
    Current Output Model:

    Fixed terminal at current is 50A, 200A, 500A

    Through-hole connection at current is 500A-5000A

    Products Shape:Stainless Steel Box
    Working condition:0 - 40ºC, RH ≤ 90%

    FY95-1 PT Burden

    Rated Voltage:100V, 100/√3V, 100/3V
    Power Factor:COSФ=0.8, COSФ=1.0
    Rated Burden (VA):

    1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA

    (more option available)

    Total Output Burden:308.75VA (more option available)
    Accuracy Class:±3%
    Operation Range:(20%-120%). Un
    Frequency:50Hz or 60Hz
    Withstand Voltage:2kV/1min
    Insulation:Air
    Operating Model:Short-time (Used in PT Accuracy Testing System)

    HJB-35G3 Standard PT

    Rated Primary Voltage:6kV, 10kV, 15kV, 22kV, 35kV, 38.5kV
    Rated Secondary Voltage:100V,110V,100/√3V,110/√3V,100/3V,110/3V

    Rated Voltage Ratio (kV):

    6/0.1, 6/√3/0.1/√3, 6/√3/0.1/3, 6/0.11, 6/√3/0.11/√3, 6/√3/0.11/3

    10/0.1, 10/√3/0.1/√3, 10/√3/0.1/3, 10/0.11, 10/√3/0.11/√3, 10/√3/0.11/3

    15/0.1, 15/√3/0.1/√3, 15/√3/0.1/3, 15/0.11, 15/√3/0.11/√3, 15/√3/0.11/3

    22/0.1, 22/√3/0.1/√3, 22/√3/0.1/3, 22/0.11, 22/√3/0.11/√3, 22/√3/0.11/3

    35/0.1, 35/√3/0.1/√3, 35/√3/0.1/3, 35/0.11, 35/√3/0.11/√3, 35/√3/0.11/3

    38.5/0.1, 38.5/√3/0.1/√3, 38.5/√3/0.1/3, 38.5/0.11, 38.5/√3/0.11/√3, 38.5/√3/0.11/3

    Accuracy Class:0.05% (100V,110V,100/√3V,110/√3V), 0.1% (100/3V,110/3V)
    Rated Secondary Burden:0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V), 0.02VA(110/3V, 100/3V)
    Power Factor:COSΦ=1.0
    Operating Range:(20%-120%). Un
    Frequency:50Hz or 60Hz
    Insulation:Epoxy resin casting

    HJB-220G3 Standard PT

    Rated Primary Voltage:110/√3kV, 220/√3kV
    Rated Secondary Voltage:110V, 110/√3V, 100V, 100/√3V

    Rated Voltage Ratio:

    110/√3/0.11/√3kV, 110/√3/0.11kV, 110/√3/0.1/√3kV, 110/√3/0.1kV

    220/√3/0.11/√3kV, 220/√3/0.11kV, 220/√3/0.1/√3kV, 220/√3/0.1kV

    Accuracy Class:0.05% (100/√3V,110/√3V), 0.1% (100V,110V)
    Rated Secondary Burden:0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V)
    Power Factor:COSΦ=1.0
    Operating Range:(20%-120%). Un
    Frequency:50Hz /60Hz
    Insulation:SF6 Gas

    SYQ-5/50 Voltage Generator

    Input Voltage:AC 0-250V
    Rated capacity:5kVA
    Rated output voltage:AC 50kV
    Output current:AC 100mA
    Measuring voltage:AC 0-100V (50kV/100V)
    Insulation:Oil
    Product Application:The product is a voltage generator, and used for inductive PT accuracy testing with 6kV-38.5kV voltage level

    HJC-80 Resonant High Voltage Source


    Product Application:

    The system is a voltage generator, and used for Capacitive PT accuracy testing with 110/√3kV and 220/√3kV voltage level
    Rated input voltage:AC 220V
    Rated output voltage:AC 0~200 kV
    Rated Capacity:200 kVar
    Max output current:AC 1.0 A
    Frequency:50Hz or 60Hz
    The capacitance of the object CVT:0.004uF ~0.02uF
    Operating Condition:Temperature: -10oC ~ +50 oC
    RH: up to 85% (max. 90%, non-condensing)

    LCB-10KVA/10KV Exciting Transformer

    Input Voltage:AC 0 - 250V, 50Hz
    Output Voltage:AC 0 - 10kV, 50Hz
    Output Current:AC 0-1A
    Rated Capacity:10kVA
    Insulation:Dry type
    Weight:~ 50 kg

    DKQ-40KVA/40KV Reactor

    Rated Capacity:40kVA/stage
    Rated Voltage:AC 40 kV/stage
    Rated Current:AC 1 A/stage
    Inductance Range:125H-500H/stage
    Insulation:Epoxy resin casting
    Weight:~ 60 kg/stage
    Quantity:5pcs

    HJF Inductive Voltage Divider


    Accuracy Class:0.001%
    Fixed Voltage Ratio:10-1, 10-2 , 10-3
    Variablle Voltage Ratio:10 x (10-1 + 10-2 + 10-3 + 10-4 + 10-5 + 10-6 + 10-7).Un
    Input Impedance:>100kΩ
    Output impedance:<3Ω
    Input Votage Range:Max AC 600V
    Output Voltage:Max AC 0~600V
    Operation Range:(20%--120%).Un
    Frequency:50/60Hz
    Temperature:5°C ~ 40°C
    Relative Humidity (RH):<85%
    Weight:~15kg

    Quality CT PT 220KV Portable Test Equipment With PC Communication Interface for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhengzhou Great Electric Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)